Recent Posts

Insertion Loss and Phase Stability Testing

Views : 487
Author : Tony Huang
Update time : 2020-05-16 15:27:25

Insertion Loss and Phase Stability Testing



1, 360 degree coil test

360 degree & -360 degree coil test



2, 180 degree bend test

180 degree & -180 degree bend test


 
 

 

We also use Heat-Aging testing and Flex Testing to test the stability of the cable.

Flex Testing

±90 degree, test S-parameter every 500 cycles



Heat-Aging Testing

48h 125℃

 